Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 476
Filtrar
1.
J Prosthet Dent ; 130(1): 35-47, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34740460

RESUMO

STATEMENT OF PROBLEM: Screwmentable prostheses were developed to combine the benefits of screw retention and cement retention. However, data are limited on the clinical performance of this type of prosthesis. PURPOSE: The purpose of this systematic review was to collect scientific evidence on screwmentable prostheses and evaluate their long-term clinical behavior. MATERIAL AND METHODS: An electronic search was conducted by 2 independent reviewers for articles published in scientific dental journals in English from 2004 to April 2020. The search strategy followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Inclusion criteria were scientific studies concerning the screwmentable type of prosthesis. RESULTS: The search provided 494 records. Of these, 24 studies fulfilled the inclusion criteria and were included in the review. The included articles presented significant heterogeneity concerning the manufacturing process and the materials used. One randomized clinical trial, 2 prospective clinical studies, 14 in vitro studies, 3 protocol descriptions, 1 case series, and 3 case reports were included. CONCLUSIONS: Based on the systematic search of the literature, it is concluded that the screwmentable prosthesis combines advantages of both cement-retained and screw-retained restorations, including passive fit, retrievability, excess cement control, tissue-friendly emergence profile, and improved esthetics. Nevertheless, data from well-designed clinical trials are limited, and further research is required to provide evidence on their long-term clinical behavior.


Assuntos
Implantes Dentários , Retenção em Prótese Dentária/métodos , Estudos Prospectivos , Prótese Dentária Fixada por Implante/métodos , Estética Dentária , Cimentos Dentários/uso terapêutico , Cimentos de Ionômeros de Vidro , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
J Prosthet Dent ; 130(1): 48-58, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34809995

RESUMO

STATEMENT OF PROBLEM: Different techniques for retrieving cement-retained implant-supported prostheses have been described to minimize damage to the prostheses. Nevertheless, a classification of the described techniques remains ambiguous. PURPOSE: The purpose of this systematic review was to review and classify the described techniques for recording and locating the screw access hole in cement-retained implant-supported prostheses. MATERIAL AND METHODS: A bibliographic search was completed on MEDLINE/PubMed, Web of Science, Scopus, and Cochrane databases. A manual search was also conducted. The articles that described or evaluated techniques for recording and locating the screw access hole of cement-retained implant-supported prostheses were included. Two investigators independently assessed the quality assessment of the studies using the Revised Cochrane risk of bias tool for randomized trials. A third examiner was consulted to resolve the lack of consensus. RESULTS: A total of 30 articles were included. The different methods were classified according to whether the screw access hole location was registered before or after cementation. The precementation techniques were classified into 4 subgroups: identification marks, photographic records, digital files, and precementation screw access hole location guides. The postcementation techniques were subdivided into 2 subgroups: radiographic records and postcementation screw access hole location guides. CONCLUSIONS: Different techniques have been proposed to facilitate the location of the screw access hole in cement-retained implant-supported restorations. Although the evidence is scarce, studies seem to ascertain that some techniques, such as the use of drilling guides, orientation with cone beam computed tomography images, or holes made in the metal framework, can increase the retrievability of cement-retained implant-supported prostheses and decrease complications in the location of the screw access hole. The proposed classification summarizes precementation and postcementation techniques and provides a tool to decide the most suitable for each specific clinical situation.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante/métodos , Retenção em Prótese Dentária/métodos , Cimentos Dentários/uso terapêutico , Cimentação/métodos , Cimentos de Ionômeros de Vidro , Parafusos Ósseos
3.
Clin Exp Dent Res ; 8(4): 1002-1007, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35618682

RESUMO

OBJECTIVES: Complete cleaning of temporary cement before permanent cementation of cement-retained implant-supported prosthesis (CISP) when recementing the crown is critical. This study evaluated the effect of different cleaning methods for removing traces of temporary cement on the final tensile bond force (TBF) of CISP recemented with resin cement. MATERIALS AND METHODS: Seventy computer-aided design/computer-aided manufacturing metal implant-supported copings were prepared and distributed into seven groups (N = 10). Copings of six groups (60 samples) were cemented with temporary cement with eugenol and subjected to 5000 thermocycling. After debonding by a universal testing machine, the internal surfaces of the copings were cleaned using one of the six following methods: 1-an ultrasonic water bath (UW), 2-sandblasting, then washing with water (SW), 3-sandblasting and an ultrasonic water bath (SUW), 4-an ultrasonic isopropyl alcohol bath (UA), 5-sandblasting, then washing with isopropyl alcohol (SA) or 6-sandblasting and an ultrasonic isopropyl alcohol bath (SUA). Then the subjects were subsequently cemented by dual-cure self-adhesive resin cement. In the seventh group (control, N = 10), the copings were cemented by dual-cure self-adhesive resin cement without the temporization phase. The TBF was tested using a universal testing machine with a cross-head speed of 1 mm/min. Two-way analysis of variance (ANOVA) and post-hoc Tamhane tests were used for statistical analysis at a significance level of α = .05. RESULTS: The maximum mean of TBF value was observed in SUA group (845 ± 203 N), and the minimum was observed in the temporary cement group (49 ± 20 N). All groups which were cleaned with isopropyl alcohol showed significantly higher TBF values compared with those cleaned with water. CONCLUSIONS: Cleaning of the inner surface of metal copings after debonding with sandblasting and isopropyl alcohol results in the highest value of TBF by eliminating the effect of remaining eugenol and removing traces of temporary cements.


Assuntos
Implantes Dentários , Cimentos de Resina , 2-Propanol , Adaptação Psicológica , Resinas Compostas , Cimentos Dentários/química , Materiais Dentários/química , Retenção em Prótese Dentária/métodos , Análise do Estresse Dentário , Eugenol , Cimentos de Ionômeros de Vidro/química , Humanos , Teste de Materiais , Cimentos de Resina/química , Cimentos de Resina/uso terapêutico , Água
4.
Int J Oral Maxillofac Implants ; 37(2): 339-345, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35476863

RESUMO

PURPOSE: To evaluate the use of a new resin metal opaquer on the surface of titanium abutments, in combination with two luting agents, and its effect on the retentive strength of implant-supported zirconia copings. MATERIALS AND METHODS: Sixty customized titanium abutments were designed and fabricated with virtual design software and a milling machine. Thirty abutment specimens were coated with metal opaquers, and the others were not coated. Then, the titanium abutments were fitted into the implant analogs, and the abutment-implant analog complexes were embedded in acrylic resin blocks. Sixty CAD/CAM-fabricated zirconia copings were seated on the abutments and secured with glassionomer cement or self-adhesive resin cement. The specimens were stored in 100% humidity for 1 hour and artificial saliva for 23 hours at 37°C before thermocycling for 5,000 cycles of 5°C to 55°C with a 30-second dwell time. The retentive strength was measured using a pull-out test with a universal testing machine. The dislodgment forces were statistically analyzed via two-way analysis of variance (ANOVA). The failure modes were evaluated and categorized by examining the fracture surface. RESULTS: The metal opaquer material had a significant negative effect on retention of zirconia copings. The nonopaquer titanium abutments showed significantly (P < .05) higher retentive strength than the metal opaquer abutments. Comparing the cements, the retentive strength values of self-adhesive resin cement were significantly higher than those of glass-ionomer cement. The metal opaquer groups exhibited mostly mixed-type failures, a combination of adhesive failures and cohesive failures, whereas the nonopaquer groups showed mostly adhesive-type failures. CONCLUSION: The titanium abutments coated with the new metal opaquer material resulted in a reduction of retentive strength. Self-adhesive resin cements exhibited significantly higher retention than glass-ionomer cements.


Assuntos
Implantes Dentários , Cimentos de Resina , Adaptação Psicológica , Dente Suporte , Cimentos Dentários , Retenção em Prótese Dentária/métodos , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro , Teste de Materiais , Propriedades de Superfície , Titânio , Zircônio
5.
PLoS One ; 17(1): e0262582, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35041706

RESUMO

This study aimed to evaluate the effects of two types of provisional resin cements on the color and retentive strength of two different all-ceramic restorations cemented onto customized zirconia abutments. Forty-two crowns were made of monolithic zirconia and lithium disilicate ceramics (n = 21 per group) and cemented on customized zirconia abutments by using two provisional resin cements of TempBond Clear and Implantlink Semi, and TempBond serving as the control (n = 7 per cement subgroup). The specimens' color was measured before and after cementation and after thermocycling. The color difference was calculated by using CIEDE2000 formula (ΔE00). The tensile force was applied to assess the retentive strength. Kruskal-Wallis, Dunn's post-hoc, and Mann-Whitney non-parametric tests were used to compare ΔE00(1) and ΔE00(2) and two-way ANOVA followed by one-way ANOVA and Tukey's HSD post hoc test and T-test were used to compare retentive strength between subgroups. In the lithium disilicate group, ΔE00 of the control subgroup (TempBond) was significantly higher than that of Implantlink Semi cements subgroup (P = 0.001). But, in the monolithic zirconia group, ΔE00 of the control subgroup (TempBond) was significantly higher than that of Implantlink Semi (P = 0.020) and TempBond Clear cements (P = 0.007). In the monolithic zirconia group, the control subgroup (TempBond) was significantly more retentive than TempBond Clear (P = 0.003) and Implantlink Semi cement (P = 0.001). However, in the lithium disilicate group, Implantlink Semi cement was significantly more retentive than TempBond Clear (P = 0.019) and TempBond (control) (P = 0.001). The final color of both restorations was significantly affected by the provisional resin cement type. The retentive strength was influenced by both the type of cement and ceramic.


Assuntos
Cerâmica/química , Cor , Dente Suporte , Retenção em Prótese Dentária/métodos , Teste de Materiais/métodos , Cimentos de Resina/química , Zircônio/química , Cimentação , Desenho Assistido por Computador , Porcelana Dentária/química , Humanos , Propriedades de Superfície
6.
Rev. Fac. Odontol. (B.Aires) ; 37(87): 7-14, 2022. ilus
Artigo em Espanhol | LILACS | ID: biblio-1537756

RESUMO

En la implantología actual, la confección de prótesis de carga inmediata se ha convertido en un procedi-miento de rutina. Contar con elementos pre-formados con un correcto ajuste al implante o transepitelial so-bre el que se trabaja, minimiza el tiempo de trabajo sin renunciar a la eficiencia. En el presente trabajo se muestran elementos preformados articulados para la realización de prótesis de carga inmediata y su forma de uso, así como un análisis biomecánico de las estructuras para conocer su repercusión en las distintas fuerzas recibidas durante la masticación. Resultados: Al aplicar la carga en la zona central de la barra (paralela a los implantes), la tensión máxima recibida en la zona correspondiente al extremo de la barra sufre variaciones importantes, desde 128 Mpa en la longitud de 13 mm hasta un máximo de 391 Mpa (megapascales) en la longitud de 5 mm, siendo la ten-sión máxima, media para todas las medidas, de 242 Mpa (+/-96,76). En el ensayo de las diferentes medi-das de la barra se observa también una tensión cre-ciente para longitudes de barra a partir de 7 mm, al aplicar la tensión en la zona media de la estructura, por lo que longitudes entre 5 y 7 mm pueden consi-derarse prácticamente con la misma distribución de tensiones hacia los extremos y en la zona de unión. En conclusión, las barras articuladas son un elemento de confección de prótesis provisionales de carga in-mediata de gran utilidad, que pueden confeccionarse de forma rápida y generan un comportamiento bio-mecánico predecible (AU)


In current implantology, the fabrication of immediately loaded prostheses has become a routine procedure. Being able to have pre-formed elements with a correct fit to the implant or transepithelial on which we are working minimizes working time without sacrificing efficiency. Material and methods: We show articulated preformed elements for immediate loading prostheses and how they are used, as well as a biomechanical analysis of the structures to determine their repercussion on the different forces received during mastication. Results: When the load is applied in the central area of the bar (parallel to the implants) the maximum stress received in the area corresponding to the end of the bar undergoes significant variations, from 128 Mpa in the 13 mm length to a maximum of 391 Mpa in the 5 mm length, the average maximum stress for all the measurements being 242 Mpa (+/-96.76). In the test of the different bar sizes we can also observe an increasing stress for bar lengths from 7 mm onwards when applying the stress in the middle zone of the structure, so that lengths between 5 and 7 mm can be considered to have practically the same stress distribution towards the ends and in the joint zone. Conclusions: Hinged bars are a very useful fabrication element for immediately loaded provisional prostheses, which can be fabricated quickly and generate a predictable biomechanical behavior (AU)


Assuntos
Fenômenos Biomecânicos , Retenção em Prótese Dentária/métodos , Planejamento de Prótese Dentária , Carga Imediata em Implante Dentário/métodos , Força de Mordida , Força Compressiva , Análise de Elementos Finitos
7.
Rev. Fac. Odontol. (B.Aires) ; 37(85): 59-66, 2022. ilus
Artigo em Espanhol | LILACS | ID: biblio-1411262

RESUMO

En este artículo se desarrolla el consenso alcanzado entre profesores, referido a los conceptos generales, componentes y la secuencia del diseño de la prótesis parcial removible, durante la formación del odontó-logo en el ámbito de la Facultad de Odontología de la Universidad de Buenos Aires (AU)


This article develops the consensus between professors on the general concepts, components, and the sequence of the design of the partial removable prosthesis during the training of the dentist in the field of the Faculty of Dentistry of the University of Buenos Aires (AU)


Assuntos
Planejamento de Prótese Dentária/métodos , Consenso , Prótese Parcial Removível , Faculdades de Odontologia , Estudantes de Odontologia , Retenção em Prótese Dentária/métodos , Oclusão Dentária , Análise do Estresse Dentário , Educação Pré-Odontológica/métodos , Docentes de Odontologia
8.
Niger J Clin Pract ; 23(8): 1073-1078, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32788484

RESUMO

AIMS: The aim of this study was to compare the retention of different luting agents used with implant-supported restorations. MATERIALS AND METHODS: A total of 90 custom metal frameworks and copings were prepared and divided into six different luting agent groups (n = 15/group): polycarboxylate cement (PC), resin-modified glass-ionomer cement (RMGIC), two self-adhesive resin cements (SARC), copper-ion zinc-phosphate cement (CZPC), and non-eugenol temporary resin cement (TRC). After sandblasting with 50 µm Al2O3, the copings were cemented on frameworks and stored in artificial saliva for 48 h at 37°C and thermocycled between 5-55°C for 37,500 cycles. Samples were subjected to tensile testing by a universal testing machine, and data were statistically analyzed. RESULTS: The differences between the retention values of types of cement were significant (P < 0.05). The maximum retention value was calculated for CZPC (755,12 ± 55 MPa) while the lowest value was for TRC (311,7 ± 61 Mpa). CONCLUSION: Neither of the tested cement had superiority over another to ensuring retention. The types of cement presented were meant to be a discretionary guide for the clinician in deciding the amount of the desired retention between castings and abutments.


Assuntos
Implantes Dentários , Retenção em Prótese Dentária , Cimentos de Ionômeros de Vidro/química , Cimento de Policarboxilato/química , Cimento de Fosfato de Zinco/química , Cimentação , Cimentos Dentários , Retenção em Prótese Dentária/métodos , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Óxido de Zinco
9.
Rev. Asoc. Odontol. Argent ; 108(1): 29-39, ene.-abr. 2020. ilus
Artigo em Espanhol | LILACS | ID: biblio-1096767

RESUMO

El objetivo de este artículo es revisar la evidencia científica existente acerca de los tipos de retención protética fija sobre implantes: atornillada, cementada y cemento-atornillada. Fueron evaluadas sus ventajas y desventajas a fin de facilitar al clínico la elección del sistema de retención en el tratamiento rehabilitador con implantes. Si bien la evidencia científica no es concluyente, la prótesis atornillada presentaría más complicaciones técnicas, y las cementadas, más complicaciones biológicas. Por ello, las prótesis cemento-atornilladas podrían ser en la actualidad una opción de elección, por su versatilidad en la rehabilitación implanto-soportada, combinando las ventajas de cada tipo de retención (AU)


The objective of this article is to review the existing scientific evidence about the different types of retention of fixed prosthetic on implants: screwed, cemented and cement-screwed. The advantages and disadvantages of them were evaluated in order to facilitate the clinician's choice of the retention system in the rehabilitation treatment with implants. Although the scientific evidence is inconclusive, the screwed prosthesis would present more technical complications, while the cemented, more biological complications. Therefore, cement-screwed prostheses could be an option of choice, due to their versatility when rehabilitating an implant, combining the advantages of each type of retention (AU)


Assuntos
Retenção em Prótese Dentária/métodos , Prótese Dentária Fixada por Implante , Coroas , Dente Suporte , Cimentação/instrumentação , Prótese Dentária Fixada por Implante/efeitos adversos , Falha de Restauração Dentária , Odontologia Baseada em Evidências
10.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 54(7): 469-474, 2019 Jul 09.
Artigo em Chinês | MEDLINE | ID: mdl-31288327

RESUMO

Objective: To compare the effect on the flow conditions of adhesives and the retention force of restorations among different cement-retained methods of implant-supported fixed prostheses. Methods: Four common cement-retained methods were selected, including the occlusal hole for screw access (OH), the lingual hole for adhesives overflow (LH), the resin replica for titanium abutment (RR), and the traditional cement-retained method (the control group). The adhesive used in this study was resin-modified glass ionomer cement. The two-dimensional analysis models of computational fluid dynamics (CFD) were established. The flow conditions of adhesives in the adhesion process was analyzed by the CFD analysis. The internal filling ratio and the amount of neck overflow of adhesives below the edge of the prosthesis were calculated. Ten zirconia prostheses in each group were processed and cemented. The retention force was examined by mechanical tensile experiments in vitro. Results: The CFD analysis showed the internal filling ratio of adhesives from high to low was the LH group, the OH group, the RR group and the control group. The amount of neck overflow of adhesives below the edge of the prosthesis from less to more was the RR group, the OH group, the LH group and the control group. The retention force was (240.7±33.9) N in the control group, (278.2±59.1) N in the OH group, (292.9±47.9) N in the LH group, and (262.8±59.4) N in the RR group. There was a statistically significant difference in the retention force between the LH group and the control group (P=0.029). There was no significant difference among the other groups (P>0.05). Conclusions: The modified cement-retained methods can effectively reduce the amount of neck overflow of adhesives, and improve the filling condition of adhesive in the adhesive clearance to ensure the retention force of the prostheses. Clinically, the appropriate modified cement-retained method should be selected according to the three-dimensional position of the implant and the position of prosthetic margin.


Assuntos
Cimentos Dentários , Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Cimentação/normas , Cimentos Dentários/normas , Retenção em Prótese Dentária/métodos , Retenção em Prótese Dentária/normas , Cimentos de Ionômeros de Vidro/normas , Humanos
11.
Int J Oral Maxillofac Implants ; 34(2): e17-e19, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30883628

RESUMO

Subgingival presence of remaining excess cement may lead to implant complications and failures. This is a technical report and advice on how to cement implant-supported restorations using a simple and universal method applying liquid petroleum jelly to the peri-implant sulcus after cementation. This simple and user-friendly method eliminates excess cement and should be used in the daily practice.


Assuntos
Cimentação/métodos , Cimentos Dentários , Retenção em Prótese Dentária/métodos , Prótese Dentária Fixada por Implante/métodos , Cimentos Ósseos , Humanos , Irrigação Terapêutica
12.
Clin Exp Dent Res ; 5(6): 594-600, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31890296

RESUMO

Objectives: Bone density, surgical protocol, and implant design are the major determinants of primary stability. The goal of this animal trial was to investigate potential correlations of intraoperative bone density testing with clinical and histologic parameters of primary implant stability. Material and methods: Following extractions of all mandibular premolars and subsequent healing, four implants each were placed in a total of four minipigs. Bone density was determined by applying intraoperative compressive tests using a device named BoneProbe whereas measurements of implant insertion torque and resonance frequency analysis were used for evaluating implant stability. Bone mineral density (BMD) and bone to implant contact were quantified after harvesting mandibular block sections. Spearman rank correlation tests were performed for evaluating correlations (α = .05). Results: Due to variation in clinical measurements, only weak correlations could be identified. A positive correlation was found between the parameters bone to implant contact and BMD (Spearman's rho .53; p = .05) whereas an inverse correlation was observed between BMD and implant stability (Spearman's rho -.61; p = .03). Both BoneProbe measurements in the cortical and trabecular area positively correlated with implant insertion torque (Spearman's rho 0.60; p = .02). A slightly stronger correlation was observed between the average of both BoneProbe measurements and implant insertion torque (Spearman's rho.66; p = .01). Conclusions: While establishing exact relationships among parameters of implant stability and the measurement techniques applied would require greater sample size, intraoperative compressive testing of bone might, despite the weak correlations seen here, be a useful tool for predicting primary implant stability.


Assuntos
Densidade Óssea , Implantação Dentária Endóssea/métodos , Implantes Dentários , Retenção em Prótese Dentária/métodos , Cuidados Intraoperatórios/métodos , Animais , Implantação Dentária Endóssea/instrumentação , Retenção em Prótese Dentária/instrumentação , Mandíbula/cirurgia , Modelos Animais , Projetos Piloto , Suínos , Porco Miniatura
13.
Clin Implant Dent Relat Res ; 21(1): 122-129, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30548792

RESUMO

PURPOSE: To assess the difference in the evolution of implant stability values, determined by resonance frequency analysis (RFA), between two groups of implants subjected to two different loading protocols: immediate and delayed. MATERIALS AND METHODS: A retrospective clinical study was conducted, including a total of 93 implants placed in 38 patients. All implants corresponded to one of two models of the Klockner Implant System (Essential Cone and Vega) and were divided into two groups according to the loading protocol adopted: delayed loading in group A (>10 weeks) and immediate loading in group B (<48 hours). Implant stability was measured four times throughout the study period with a Penguin RFA device: implant placement (T0), definitive loading (T1), 6 months after loading (T2), and 12 months after loading (T3). RESULTS: Implant stability quotient (ISQ) values showed a statistically significant increase in both groups after loading. In group A, the greatest increase in stability occurred between T1 and T2, whereas in group B, the greatest increase occurred between T0 and T1, coinciding in both cases with the period in which the implants were subjected to prosthetic loading. CONCLUSIONS: The functional loading of implants increases their stability, as measured in ISQ values by RFA. Increases in ISQ values are greater during the months immediately following loading, which shows that immediate or early loading protocols are not only possible but can also be beneficial.


Assuntos
Implantação Dentária Endóssea , Retenção em Prótese Dentária , Implantação Dentária Endóssea/métodos , Retenção em Prótese Dentária/métodos , Feminino , Humanos , Carga Imediata em Implante Dentário/métodos , Masculino , Pessoa de Meia-Idade , Análise de Frequência de Ressonância , Estudos Retrospectivos
14.
J Prosthodont ; 28(2): e705-e712, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29522263

RESUMO

PURPOSE: To evaluate the biocompatibility of five dental cement compositions after directly exposing human gingival fibroblast (HGF) and MC3T3-E1 preosteoblast cells to cement alone and cement applied on commercially pure titanium (cpTi) specimens. MATERIALS AND METHODS: Nanostructurally integrated bioceramic (NIB), resin (R), resin-modified glass ionomer (RMGIC), zinc oxide eugenol (ZOE), and zinc phosphate (ZP) compositions were prepared according to the respective manufacturer's instructions. Samples were prepared in cylindrical Teflon molds or applied over the entire surface of polished cpTi discs. All samples were cured for 0.5, 1, 12, or 24 hours post-mixing. Direct contact testing was conducted according to ISO 10993 by seeding 6-well plates at 350,000 cells/well. Plates were incubated at 37°C in a humidified atmosphere with 5% CO2 for 24 hours before individually plating samples and cpTi control discs. Plates were then incubated for an additional 24 hours. Microtetrazolium (MTT) cell viability assays were used to measure sample cytotoxicity. RESULTS: For samples that cured for 24 hours prior to direct contact exposure, only NIB and ZP cements when cemented on cpTi demonstrated cell viability percentages above the minimum biocompatibility requirement (≥70%) for both the investigative cell lines. R, RMGIC, and ZOE cements exhibited moderate to severe cytotoxic effects on both cell lines in direct contact and when cemented on cpTi specimens. For HGF cells, ZOE cemented-cpTi specimens exhibited significantly decreased cytotoxicity, whereas RMGIC cemented-cpTi specimens exhibited significantly increased cytotoxicity. CONCLUSIONS: Despite previous studies that showed enhanced cpTi corrosion activity for fluoride-containing compositions (NIB and ZP), there was no significant difference in cytotoxicity between cement alone and cemented-cpTi. In general, the MC3T3-E1 preosteoblast cells were more sensitive than HGF cells to cement composition. Ultimately, cement composition played a significant role in maintaining host cell compatibility. Results of this work help illustrate the impact of different cement formulations on host cell health and emphasize the need for understanding material properties when selecting certain formulations of dental cements, which can ultimately influence the survival of dental implant systems.


Assuntos
Materiais Biocompatíveis , Cimentos Dentários/uso terapêutico , Implantes Dentários , Titânio , Sobrevivência Celular/efeitos dos fármacos , Cerâmica/uso terapêutico , Retenção em Prótese Dentária/métodos , Fibroblastos , Gengiva/citologia , Cimentos de Ionômeros de Vidro/uso terapêutico , Humanos , Técnicas In Vitro , Teste de Materiais/métodos , Nanoestruturas/uso terapêutico , Cimento de Óxido de Zinco e Eugenol/uso terapêutico , Cimento de Fosfato de Zinco/uso terapêutico
15.
J Prosthodont ; 28(2): e771-e779, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30168651

RESUMO

PURPOSE: The aim of this study was to compare survival rates, marginal bone loss (MBL), and peri-implant soft tissue parameters between short and standard laser-microgrooved implants supporting single or splinted crowns 3 years after loading. MATERIALS AND METHODS: 30 subjects received 1 short ( ≤ 7 mm ) and 1 standard length ( ≥ 9 mm ) laser-microgrooved implant in adjacent sites of the premolar and molar regions of the mandible or maxilla. Peri-implant soft tissue parameters and intraoral radiographs were recorded at the delivery of definitive crowns (baseline) and 3 years later. Cumulative survival rate (CSR) and marginal bone loss (MBL) in relation to crown/implant (C/I) ratio, implant length, location, type of antagonist, and type of prosthetic design (single or splinted), were evaluated. RESULTS: CSR of short implants was 98%, compared to 100% for standard implants, without significant statistical difference. MBL was not significantly different over the observation period, with an average of 0.23 ± 0.6 mm and 0.27 ± 0.3 mm for short and standard implants, respectively. No statistical differences were found between short and standard implants regarding plaque (14.7% vs. 15.7%), number of sites BOP (8.3% vs. 5.9%), probing depth (1.13 ± 0.6 mm vs. 1.04 ± 0.8 mm), and mean mucosal recession (0.18 ± 0.3 mm vs. 0.22 ± 0.3 mm). Analyzing MBL in relation to the C/I ratio, implant length, location, type of antagonist, and type of prosthetic design, no statistically significant differences were found. CONCLUSION: Regardless of C/I ratio, implant length, location, type of antagonist, and type of prosthetic design, short and standard laser-microgrooved implants had similar survival rates, MBL, and peri-implant soft tissue conditions over the observation period of 3 years.


Assuntos
Coroas , Planejamento de Prótese Dentária/métodos , Prótese Dentária Fixada por Implante , Adulto , Idoso , Idoso de 80 Anos ou mais , Perda do Osso Alveolar/epidemiologia , Perda do Osso Alveolar/etiologia , Implantes Dentários , Retenção em Prótese Dentária/métodos , Prótese Dentária Fixada por Implante/métodos , Falha de Restauração Dentária , Feminino , Seguimentos , Humanos , Lasers , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia Dentária , Adulto Jovem
16.
Angle Orthod ; 89(2): 284-291, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30382751

RESUMO

OBJECTIVES: To develop and validate a method for application of the Osstell ISQ device in the assessment of mini-implant stability. MATERIALS AND METHODS: An adaptor was developed for attachment of Osstell's SmartPeg onto a variety of orthodontic mini-implants. For validation of the adaptor, Benefit mini-implants were inserted into bone blocks that mimicked different stability conditions. The Osstell device was used to assess mini-implant stability with the adaptor (test measurement) and conventional SmartPeg attachment (gold-standard measurement). Implant stability quotient (ISQ) values were assessed for agreement, repeatability, and reproducibility. RESULTS: Strong positive correlations were found between ISQ values obtained using the novel adaptor and the conventional attachment. Repeatability and reproducibility of ISQ values with the adaptor were similar to those obtained with the conventional attachment. CONCLUSIONS: A method was developed and validated to assess the stability of orthodontic mini-implants using the Osstell system. The novel mini-implant adaptor provided repeatable and reproducible measurements of mini-implant stability, which agreed with those obtained using a conventional SmartPeg attachment. This adaptor permits noninvasive stability assessment of various designs of mini-implants, most of which are incompatible with the conventional SmartPeg attachment.


Assuntos
Implantes Dentários , Retenção em Prótese Dentária , Retenção em Prótese Dentária/métodos , Reprodutibilidade dos Testes , Vibração
17.
J Prosthodont ; 28(1): e210-e215, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28598530

RESUMO

PURPOSE: To evaluate the effect of temporary cement cleaning methods on the retention of cemented crowns using zinc phosphate cement and resin-modified glass ionomer cement. MATERIALS AND METHODS: Forty titanium specimens were fabricated to simulate prepared molars with minimally retentive taper. The Ni-Cr cast crowns were fabricated, temporarily cemented, and separated. The specimens were divided into four groups according to the temporary cement cleaning method (n = 10) as follows: control group (no temporary cementation), orange solvent group, ultrasonic cleaning group, and air-abrasion group. After the cleaning procedures, the specimens were cemented with definitive cements (zinc phosphate cement and resin-modified glass ionomer, RMGI, cement) and subjected to thermocycling (5000 cycles, 5-55°C, dwell time, 10 seconds). The tensile bond strength of each specimen was measured using a universal testing machine, and the results were analyzed using the Kruskal-Wallis and Mann-Whitney U test (α = 0.05). RESULTS: When cemented with zinc phosphate cement, the statistical analysis showed that the value of the air-abrasion group was significantly higher than those of the other groups (p < 0.01). There was no statistically significant difference among the other groups. When cemented with RMGI cement, the air-abrasion group showed the lowest value, and the control group showed the highest value (p < 0.01). The difference between the ultrasonic cleaning group and the orange solvent group was not statistically significant. CONCLUSION: The use of temporary cement did not have a significant influence on retention of permanently cemented crowns when zinc phosphate cement was used for permanent cementation. Airborne-particle abrasion after provisional cementation improved retention of crowns cemented with zinc phosphate cement; however, the use of temporary cement significantly decreased retention of permanently cemented crowns when RMGI cement was used regardless of the temporary cement cleaning method.


Assuntos
Cimentação/métodos , Cimentos Dentários/química , Retenção em Prótese Dentária/métodos , Cimentos de Ionômeros de Vidro/química , Teste de Materiais , Abrasão Dental por Ar/métodos , Coroas , Materiais Dentários/efeitos adversos , Análise do Estresse Dentário , Detergentes/uso terapêutico , Humanos , Resistência à Tração , Terapia por Ultrassom/métodos , Cimento de Fosfato de Zinco/química
18.
J Prosthodont ; 28(2): 179-184, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28102922

RESUMO

PURPOSE: To evaluate in vitro the effect of the size of the unfilled space of the abutment screw access hole on the amount of extruded excess cement and the retention of zirconia copings. MATERIALS AND METHODS: Twelve dental implant replicas were attached to the corresponding abutments and embedded in acrylic resin blocks. A total of 36 CAD/CAM zirconia copings were fabricated by one technician using the standard technique. Abutments were divided into group I: the entire screw access channel was completely filled (nonspaced); group II: 1-mm-spaced; and group III: 2-mm-spaced. The copings were air-abraded and temporarily cemented under constant load of 60 N for 10 minutes. The excess cement was calculated as the difference between the post-cementation and post-excess-removal weights using a digital scale. Retention test was performed by a universal testing machine at a 0.5 mm/min crosshead speed. The ultimate force and tensile strength required for separation were recorded. One-way ANOVA and Tukey's test were used for statistical analysis at p ˂ 0.05. RESULTS: The average amount of extruded cement in groups 1, 2, and 3 was 33.48 ± 1.55, 23.05 ± 5.48, and 15.58 ± 5.98 mg, respectively. Multiple comparisons showed significant differences in the amount of extruded excess cement between the three groups (p ˂ 0.001). The maximum load at decementation in groups 1, 2, and 3 was 98.8, 87.5, and 88.6 N, respectively. Groups 1, 2, and 3 separated at 6.90 ± 1.2, 6.12 ± 0.7, and 6.21 ± 0.9 MPa, respectively, with no significant differences between them. CONCLUSIONS: The amount of extruded excess cement was reduced by more than half when a 2-mm space of the screw access hole was left unfilled in comparison to the nonspaced counterpart. The retention of zirconia copings was not affected by the reported technique.


Assuntos
Parafusos Ósseos , Coroas , Dente Suporte , Cimentos Dentários/química , Retenção em Prótese Dentária/métodos , Prótese Dentária Fixada por Implante , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Resistência à Tração , Zircônio/química
19.
J Prosthodont ; 28(2): e739-e743, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29855135

RESUMO

PURPOSE: The metal framework of implant-supported restorations can be made using different methods. For a successful outcome, the acceptability of each method depends on the retention and fit of the restoration. The aim of this study was to evaluate and compare the retention and adaptation of copings fabricated using two methods: casting wax patterns made by computer-aided design/computer-aided manufacturing (CAD/CAM) technology, and milling sintered chromium-cobalt (Cr-Co) blocks. MATERIALS AND METHODS: Twenty-four abutment analogs (height, 5.5 mm) were divided into two groups according to the framework fabrication method. In one group, wax patterns were prepared using a CAM milling machine, and they were cast with a Ni-Cr-Ti metal alloy. In the second group, the copings were milled from Cr-Co blocks using a CAD/CAM milling machine. All copings were equal in contour, thickness, and internal relief and were seated on the abutment analogs after the necessary adjustments. The vertical marginal discrepancy was investigated using a silicone replica method and stereomicroscope with 75× magnification. After copings were cemented onto the abutment analogs using zinc phosphate, a tensile resistance test was performed using a universal testing machine. Mann-Whitney U and Student's t-test were used for statistical analyses at a significance level of 0.05. RESULTS: An independent sample t-test revealed a significant difference between the two groups for retention (p = 0.010), and the milled wax group showed higher tensile resistance compared with the milled metal group. There was also a significant difference between the two groups in marginal discrepancy (p < 0.001), with a larger marginal gap in the milled metal group compared with the milled wax group. The milled metal copings required more adjustments to fit on the abutment analogs compared with the wax milled copings (p < 0.001). CONCLUSIONS: The CAD/CAM technique for wax milling resulted in more retentive copings with better marginal and internal adaptations compared with milling the metal blocks.


Assuntos
Ligas de Cromo , Desenho Assistido por Computador , Técnica de Fundição Odontológica , Adaptação Marginal Dentária , Planejamento de Prótese Dentária/métodos , Retenção em Prótese Dentária/métodos , Dente Suporte , Projeto do Implante Dentário-Pivô/métodos , Prótese Dentária Fixada por Implante/métodos , Humanos , Técnicas In Vitro , Ceras
20.
J Prosthet Dent ; 121(1): 52-58, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30006223

RESUMO

STATEMENT OF PROBLEM: Cement-retained implant-supported prostheses eliminate screw loosening and enhance esthetics. However, retrievability and the possibility of removing extruded excess cement (EEC) have been problematic. PURPOSE: The purpose of this systematic review was to analyze the effects of modifying the screw access channel (SAC) on the amount of EEC and the retention of cement-retained implant-supported prostheses. MATERIAL AND METHODS: PubMed, Web of Science, Scopus, and Google Scholar databases were searched with appropriate key words. Related titles and abstracts published up to June 2017 were screened and selected on the basis of defined inclusion criteria. Full texts of all studies were read and subjected to quality assessments. After the initial search, 1521 articles were included in the study. Of these, 11 studies were subjected to critical appraisal, and 10 of them were reliable enough in methodology to be systemically reviewed. RESULTS: All the studies were in vitro and described a total of 260 specimens. According to the interpreted results, closed SACs caused lower retention with a higher amount of EEC, whereas open SACs caused the reverse. Also, as the abutment height decreased, retention decreased. CONCLUSIONS: Extending the crown's margin into the SAC, leaving the SAC open, and using internal vents in the SAC space are possible methods of modifying the SAC to gain higher retentive values. Also, the use of internal vents in the SAC system and open or partially filled SAC space reduce the amount of EEC.


Assuntos
Parafusos Ósseos , Cimentos Dentários/efeitos adversos , Implantes Dentários , Retenção em Prótese Dentária/métodos , Prótese Dentária Fixada por Implante/métodos , Coroas , Bases de Dados Factuais , Dente Suporte , Falha de Restauração Dentária , Restauração Dentária Permanente/métodos , Restauração Dentária Temporária/métodos , Estética Dentária , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...